Rectangular fire damper CU2L

Wide-ranging rectangular fire damper up to 120’

Rectangular fire damper with a tunnel casing extension at one or both sides. This extension of our rectangular fire damper is used so that the damper blade does not exceed the tunnel. This version allows to connect a grill or a bend directly on the damper flange or to use a circular connection.

Available dimensions (Hn/Wn): 200×200 mm > 1500x1000mm

Benefits:
  • Large dimensions
  • The rectangular fire damper has many options and variants
  • Battery assembly tested in rigid wall
  • Model available for use in potentially explosive atmospheres
Components:
  1. Connection flange PG30
  2. Casing made of refractory material
  3. Damper blade
  4. Operating mechanism
  5. Sealing cold smoke
  6. Blade bumper
  7. Intumescent strip
  8. Transmission with locking (open/closed)
  9. Fusible link
  10. Product identification
  11. Graphite strip
  12. Wall limit
Features:
  • Extension: a = Hn/2-230 mm (on the side of the mechanism); b = Hn/2-100 mm (on the wall side)
Mechanisms:

Download Technical datasheet KIT

The unlocking mechanism CFTH automatically unlatches the damper blade when the temperature in the duct rises above 72°C. The damper can also be unlocked and reset manually.

1. Unlocking button
2. Resetting handle
3. Cable entrance

VARIANTS

  • CFTH
    Mechanism with fusible link

OPTIONS – SWITCH

  • FCU
    Limit switch ‘open/closed’
  • FDCU
    Unipolar limit switch ‘open/closed’
  • FDCB
    Bipolar auxiliary limit switch ‘open/closed’

UNLOCKING

  • manual unlocking
    press the unlocking button (1).
  • automatic unlocking
    the fusible link melts when the temperature reaches 72°C in the duct.
  • remote unlocking
    n/a

RESETTING

  • manual resetting
    Use the enclosed Hex key and turn clockwise(2)
  • motorised resetting
    n/a

Download Technical datasheet KIT

The spring-return actuator ONE is designed to easily operate Rf-t fire dampers of all sizes, automatically or remotely. Six models are available, 24 or 230 volt, with FDCU or FDCB position switches; and optionally with plug (ST).

  1. Unlocking button
  2. Blade position indicator
  3. LED
  4. Battery compartment to reset motor
  5. Plug (ST)

VARIANTS

  • ONE T 24 FDCU ST
    Spring return actuator ONE 24V (with fusible link) + unipolar beginning- and end-of-range switch and plug (ST)
  • ONE T 24 FDCU
    Spring return actuator ONE 24V (with fusible link) + unipolar beginning- and end-of-range switch
  • ONE T 230 FDCU ST
    Spring return actuator ONE 230V (with fusible link) + unipolar beginning- and end-of-range switch + plug (ST)
  • ONE T 230 FDCU
    Spring return actuator ONE 230V (with fusible link) + unipolar beginning- and end-of-range switch
  • ONE T 24 FDCB
    Spring return actuator ONE 24V (with fusible link) + bipolar beginning- and end-of-range switch
  • ONE T 230 FDCB
    Spring return actuator ONE 230V (with fusible link) + bipolar beginning- and end-of-range switch

UNLOCKING

  • manual unlocking
    shortly press the unlocking button (1) once.
  • automatic unlocking
    the fusible link reacts as soon as the temperature in the duct reaches 72°C.
  • remote unlocking
    by interrupting the power supply.

RESETTING

  • manual resetting
    open the battery compartment (4) and press a 9V battery against the contact springs. Hold this position until the LED (3) emits a continuous light. Check whether the indicator (2) shows that the damper blade is in the open position. Remove the battery, the LED fades away. Close the battery compartment.
  • motorised resetting
    switch off the power supply for at least 5 sec. Power the actuator (respect the prescribed voltage) for at least 75 sec. The resetting stops automatically when the end of range is reached (damper open).

Download Technical datasheet KIT

The ONE-X is a spring return actuator with integrated communication module designed to simply operate Rf-t fire dampers of all sizes, automatically or remotely. The ONE-X is available in two versions: 24 V and 230 V.

  1. Unlocking button
  2. Blade position indicator
  3. LED red: status
  4. Battery compartment
  5. LED blue: communication
  6. LED orange: error message
  7. Supply
  8. Bus cable
  9. Bus cable

VARIANTS

  • ONE-X 24
    Spring return actuator ONE-X 24V (with fusible link T) with integrated communication module
  • ONE-X 230
    Spring return actuator ONE-X 230V (with fusible link T) with integrated communication module

UNLOCKING

  • manual unlocking
    shortly press the unlocking button (1) once.
  • automatic unlocking
    the fusible link reacts as soon as the temperature in the duct reaches 72°C.
  • remote unlocking
    via ZENiX controller

RESETTING

  • manual resetting
    Open the battery compartment (4) and press a 9V battery against the contact springs. Hold this position until the red LED (3) emits a continuous light. Control whether the indicator (2) indicates that the damper blade is open. Remove the battery. Close the battery compartment.
  • motorised resetting
    via ZENiX controller. By applying voltage during first use.

Download Technical datasheet KIT

The spring return actuator BFL(T) is especially designed to operate fire dampers remotely. The BFL(T) variant is intended for fire dampers with smaller dimensions (CR60, CR120, CR2 with ø ≤ 400 mm, CRS60 with ø ≤ 315 mm, CU2 / CU2-15 / CU4 with B+H ≤ 1200 mm or for CU-LT and CU-LT-1s). For Markage FD with H = 200 mm or H = 2200 mm (in combination with BFT motor).

  1. Locking button
  2. Plug (ST)
  3. Access for manual resetting
  4. Thermo-electric tripping device (T)

VARIANTS

  • BFL24
    Spring return actuator BFL 24V
  • BFL24-ST
    Spring return actuator BFL 24V with plug (ST)
  • BFL230
    Spring return actuator BFL 230V
  • BFLT24
    Spring return actuator BFL 24 V with thermo-electric fuse (T)
  • BFLT24-ST
    Spring return actuator BFL 24 V with thermo-electric fuse (T) and plug (ST)
  • BFLT230
    Spring return actuator BFL 230 V with thermo-electric fuse (T)
  • BFLT230-ST
    Spring return actuator BFL 230 V with thermo-electric fuse (T)

OPTIONS – SWITCH

  • SN2 BFL/BFN
    Auxiliary limit switch ‘open/closed’

UNLOCKING

  • manual unlocking
    place the locking button on “unlock”. (In case of BFLT: the damper can alternatively be unlocked by pushing the “test” button on the thermo-electric fuse)
  • automatic unlocking
    the thermo-electric fuse reacts as soon as the temperature reaches 72°C (type BFLT).
  • remote unlocking
    by interrupting the power supply.

RESETTING

  • manual resetting
    turn the enclosed handle anti-clockwise. To block the motor, place the locking button on “lock”
  • motorised resetting
    switch off the power supply for at least 10 seconds. Supply the actuator (respect the prescribed voltage) for at least 75 seconds. The resetting stops automatically when the end of range is reached (damper open) – it takes about 60 seconds to reset the damper – or when the power supply is interrupted.

Download Technical datasheet KIT

The spring return actuator BFN(T) is especially designed to operate fire dampers remotely. The BFN(T) variant is intended for fire dampers with large dimensions (CRE60, CR2 with ø > 400 mm, CRS60 with ø > 315 mm or CU2, CU2-15, CU4 with B+H > 1200 mm. For Markage FD with H of 400 and 600 mm or with H = 1200 mm (2 pcs) and with H = 2400 mm (in combination with BFT motor).

  1. Locking button
  2. Plug (ST)
  3. Access for manual resetting
  4. Thermo-electric tripping device (T)

VARIANTS

  • BFN24
    Spring return actuator BFN 24V
  • BFN24-ST
    Spring return actuator BFN 24V with plug (ST)
  • BFN230
    Spring return actuator BFN 230V
  • BFNT24
    Spring return actuator BFN 24 V with thermo-electric fuse (T)
  • BFNT24-ST
    Spring return actuator BFN 24 V with thermo-electric fuse (T) and plug (ST)
  • BFNT230
    Spring return actuator BFN 230 V with thermo-electric fuse (T)

OPTIONS – SWITCH

  • SN2 BFL/BFN
    Auxiliary limit switch ‘open/closed’

UNLOCKING

  • manual unlocking
    place the locking button on “unlock”. (In case of BFNT: the damper can alternatively be unlocked by pushing the “test” button on the thermo-electric fuse)
  • automatic unlocking
    the thermo-electric fuse reacts as soon as the temperature reaches 72°C (type BFNT).
  • remote unlocking
    by interrupting the power supply.

RESETTING

  • manual resetting
    turn the enclosed handle anti-clockwise. To block the motor, place the locking button on “lock”
  • motorised resetting
    switch off the power supply for at least 10 seconds. Supply the actuator (respect the prescribed voltage) for at least 75 seconds. The resetting stops automatically when the end of range is reached (damper open) – it takes about 60 seconds to reset the damper – or when the power supply is interrupted.

Download the technical brochure of the CU2 series

Dear,

Thank you for expressing interest in our products. We are delighted to provide you with the technical brochure of the CU2 series. We appreciate your enthusiasm and look forward to assisting you further on your journey.

To download the brochure, please click the button below:

We hope that our product brochure provides you with comprehensive insights into the features and benefits of the CU2 series. If you have any questions or require additional information, please don’t hesitate to reach out to our friendly sales & support team. 

Thank you again for choosing Rf-Technologies. 

 

Best regards,

Tony Readdy

Technical Sales Expert UK

M. 07939 316006 | tony.readdy@rft.eu

Quotation request: